Application:
Reagents CL-1 and CL-2 can be used together for photometric immersion of free active chlorine, reagent CL-3 can be used in addition to the two above reagents for photometric immersion of all chlorine.

Neither of these reagents can be used alone with any other type of reagent.

 

Storage. Keep containers closed and protected from contamination.

 

MEASUREMENT PROCEDURE:

Free active chlorine:

Fill the photometer cuvette with 10 ml of water sample.
Fill the photometer with 10 ml of water solution.
Add 3 drops of CL-1 and 2 drops of CL-2 reagent to the sample.
Start the free active chlorine measurement on the photometer and read the result.


Total chlorine:

Add 3 drops of CL-3 reagent to the same sample.
Start the total chlorine measurement on the photometer and read the result.
The bound chlorine value is the difference between the total chlorine value and the free active chlorine value.

 

 

Keep the product container or label handy for medical advice.
Keep out of the reach of children.
Inhalation of dust/fumes/gas/mist/vapours/spray is prohibited.
In case of sickness seek medical attention.
Disposal of contents/container as waste: as hazardous waste according to local regulations.

Hazardous ingredients: potassium iodide, 5 - <10 % (CAS:7681-11-0)

Hazard Information:
Danger: Causes damage to organs (or state all organs affected, if known) through prolonged or repeated exposure (state route of exposure if it is conclusively proven that no other routes of exposure cause the hazard).
Reagent HydroQuant Cl-1 16 ml Reagent HydroQuant Cl-1, Wapotec reagent
Net price: 10.68 EUR
Gross price: 13.56 EUR
Read more
Reagent HydroQuant Cl-2 12 ml Reagent HydroQuant Cl-2 12 ml
Net price: 10.68 EUR
Gross price: 13.56 EUR
Read more
Not found documentation.
We use cookies to ensure you get the best experience on our website. More information

  havi_akcio_szegelytisztito_02